Partial Discharge Corona Test System

  • GIT-450kVA/150kV PD-free AC Dielectric Test Set

    GIT-450kVA/150kV PD-free AC Dielectric Test Set

    The GIT-450kVA/150kV PD-free AC Dielectric Test Set is an advanced automatic withstand voltage tester designed in accordance with the latest national power industry standards. It utilizes PLC controller technology, 2.4G ISM networking, and an advanced human-machine interface. This test equipment is suitable for power frequency withstand voltage testing and partial discharge testing of high-voltage electrical equipment of 150kV and below.The max. capacitance of tested object is 0.05μF at 150kV.

  • GDYT-10/100  Partial Discharge Testing System 10kVA/100kV

    GDYT-10/100 Partial Discharge Testing System 10kVA/100kV

    This set of equipment is mainly used for partial discharge measurement and other scientific experimental research.

  • Partial Discharge Test System GDYT series

    Partial Discharge Test System GDYT series

     It widely used in electrical manufacturing, power operation departments, research institutes and universities.

     

     

     

  • PD Free Variable Frequency Test System

    PD Free Variable Frequency Test System

    GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider. 

     

     

     

     

     

     

  • Partial Discharge Test System GIT series

    Partial Discharge Test System GIT series

    GIT series is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer.

     

     

     

     

     

     

  • GDYT-10/100 High Precision Partial Discharge Testing System for Electrical Equipment

    GDYT-10/100 High Precision Partial Discharge Testing System for Electrical Equipment

    GDYT-10/100 Partial Discharge Test System is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It is widely used in electrical manufacturing, power operation departments, research institutes and universities.

Send your message to us:

Write your message here and send it to us